Guidelines
RECOMMENDED PROCEDURES FOR DISPOSAL OF WASTE BATTERIES
|
|
GENERAL
TYPES |
RECOMMENDED
DISPOSAL PROCEDURES |
|
1 |
Dry Cell Battery |
· Waste dry cell batteries should be placed in separate double polyethylene
bags before disposal in landfill. |
|
2 |
Lithium Battery Small
sealed type lithium battery
- used in electronic equipment e.g. cameras, wrist watches etc. Large
wet type lithium battery (w/draining ports for electrolyte) – used in power back-up systems for electronic
circuit boards and similar applications. |
· Lithium batteries should be handled with care. It should not be opened
or burned. · Waste small sealed type lithium battery should be placed inside double
polyethylene bags before disposal in landfill. · Waste large wet type lithium battery (w/draining ports for electrolyte)
should be recycled. The originator of the waste must ensure
the following precautions are followed. I. Large wet type waste lithium batteries should be stored in a well
ventilated dry area at temperatures below 70ºC. The optimum storage
temperature is -10ºC to + 25ºC. There is the risk of fire, explosion
and burns if the lithium battery is crushed, recharged, disassembled
or heated above 100ºC. |
|
|
|
II. Large wet type waste lithium batteries are
equipped with a draining port for the electrolyte. The electrolyte
must not be drained. If electrolyte come into contact with the skin
flush with warm soap water. |
|
|
|
III. The large wet type waste lithium batteries
should be fully discharged before disposal. Do not short circuit the
lithium battery. This may produce high temperature and subsequent
cell rupture. In case of fire use dry powder extinguisher based on
graphite (LITH-X) or other suitable extinguishers designed for alkali
metal fires. Water, CO2 or halon extinguishers must NOT
be used. |
|
|
|
IV. The wet type waste lithium batteries should
be kept in a proper/safe storage facility until a commercial size
is accumulated to be sent for recycling. Proper handling procedures
should be adhered to ensure environmentally safe movement/transport
of the waste batteries. |